Dr Chris Russo

Group Leader, Structural Studies Division, MRC Laboratory of Molecular Biology


Born in Detroit Michigan, Chris attended the University of Notre Dame where he studied electrical engineering and philosophy. He then went on to graduate school at Harvard and MIT, where he studied physics and medicine under the supervision of Jene Golovchenko (Physics, Engineering) and Daniel Branton (Biology). During this time, he developed a new technique to create nanopores for DNA sequencing in graphene with atomic precision that combined ion bombardment with high energy electron irradiation.

He then moved to the MRC Laboratory of Molecular Biology in Cambridge UK to work on developing new methods for electron cryomicroscopy (cryo-EM). Chris has since started his own group at LMB, and continues to study the physical phenomena that limit resolution in cryo-EM and thus enable the development of new devices, instruments and methods to improve the imaging power of the electron microscope in biology.

http://www.mrc-lmb.cam.ac.uk/crusso


Abstract: What is the best energy for imaging molecules with electrons?

Radiation damage sets the ultimate limit to structure determination using any form of ionising radiation with sufficient energy to resolve the positions of atoms in a molecule. Electrons, since they interact strongly with biological specimen, induce severe radiation damage, but also provide maximal contrast per unit damage event when compared to X-rays and neutrons. While the amount of information per unit damage for electrons is thought to be approximately constant over the energy range of 10 to 1000 keV, published measurements of radiation damage to biological specimen are not of sufficient accuracy to determine if there is an advantage, in terms of contrast per unit damage, to reducing or increasing the energy of the electron beam. Recently, our measurements of specimen charging and the demonstration of Ewald sphere correction indicate that neither of these present a barrier for reducing the energy of the electron beam from 300 keV, which is the current standard for most commercial high-resolution electron cryomicroscopes. Some theoretical estimates indicate that the ratio of the inelastic to elastic scattering cross sections for carbon may drop significantly as the energy is reduced. With this in mind, we wish to understand both theoretically and experimentally, if there is a potential advantage in changing the energy of the electron from the conventional 300 keV used for most cryoEM. Here we present our recent progress in measuring how the amount of structural information in electron cryomicrographs of biological specimen scales vs. damage when changing the energy of the incident electron beam. We measure the high energy elastic scattering cross sections of carbon to high accuracy using pure carbon specimens. We compare these data to established theory of electron scattering as well as measurements of damage using the fading of diffraction spots from 2D crystals of paraffin and bacteriorhodopsin (purple membrane). Finally, we present a demonstration of the first atomic structures of a range of protein specimens determined at 100 keV. From this work, we conclude that determining the structures of biological macromolecules continues to improve, largely though improvements to electron microscopy made through studying the physical limits of imaging with high energy electrons.  


Environmental Statement   Modern Slavery Act   Accessibility   Disclaimer   Terms & Conditions   Privacy Policy   Code of Conduct   About IOP         


© 2021 IOP All rights reserved.
The Institute is a charity registered in England and Wales (no. 293851) and Scotland (no. SC040092)